Model | ALK-1201 | ALK-1301 | ALK-1231 |
Configuration | Power Meter + Light Source | Power Meter+Visual Fault Locator(10mw) | Power Meter+Light Source+Visual Fault Locator ( 10mw ) |
Optical Power Meter Module |
Detector Type | InGaAs |
Measurement Range(dBm) | -70~+6 | -50~+26 |
Uncertainty | 5% |
Calibrated wavelengths(nm) | 850、1300、1310、1490、1550、1625 |
Resolution(dB) | 0.01 |
Optical Connector | FC(interchangeable SC,ST) |
Optical Light Source Module |
Emitter Type | FP-LD |
Wavelengths | 1310/1550(other wavelengths can be optional) |
Ouput Power(dBm) | -7 |
Spectral Width | ≤10nm |
Output Stability | ±0.05dB/15mins; ±0.1dB/ 8hours |
Optical Connector | FC/ PC |
General Specifications of Multi Meter |
Power Supply | Alkaline Battery(3 AA 1.5V batteries) |
Battery Operating Time | ≥60 hours(Both Power Meter and Ligh Source are working) ≥240hours(Only Power Meter is working) |
Auto-off time | 10mins |
Operating Temperature(℃) | -10~+60 |
Storage Temperature(C) | -25~+70 |
Dimension(mm) | 200 X90 X50 |
Weight(g) | 285 |